PERFORMANCE |
ENGLISH |
SI |
Sensitivity(± 10 %) |
100 mV/in/sec |
|
Measurement Range |
± 50 in/sec |
|
Frequency Range(± 10 %)
|
240 to 270,000 cpm |
|
Frequency Range(± 3 dB)
|
180 to 540,000 cpm |
|
Resonant Frequency |
1200 kcpm |
|
Broadband Resolution(1 to 10,000
Hz) |
450 µin/sec |
|
Non-Linearity |
± 1 % |
|
Transverse Sensitivity
|
≤ 5 % |
|
ENVIRONMENTAL |
|
|
Overload Limit(Shock) |
5000 g pk |
|
Temperature Range |
-65 to +250 °F |
|
Temperature Response |
See Graph |
|
ELECTRICAL |
|
|
Settling Time(within 1% of
bias) |
≤ 30 sec |
|
Excitation Voltage |
18 to 28 VDC |
|
Constant Current
Excitation |
2 to 10 mA |
|
Output Impedance |
<100 ohm |
|
Output Bias Voltage |
8 to 12 VDC |
|
Spectral Noise(10 Hz) |
40 µin/sec/√Hz |
|
Spectral Noise(100 Hz)
|
7.0 µin/sec/√Hz |
|
Spectral Noise(1 kHz) |
0.4 µin/sec/√Hz |
|
Electrical Protection |
RFI/ESD |
|
Electrical Isolation |
>108 ohm
|
|
PHYSICAL |
|
|
Size (Hex x Height) |
7/8 in x 2.06 in |
|
Weight |
3.3 oz |
|
Mounting Thread |
1/4-28 Female |
|
Mounting Torque |
2 to 5 ft-lb |
|
Sensing Element |
Ceramic |
|
Sensing Geometry |
Shear |
|
Housing Material |
Stainless Steel |
|
Sealing |
Welded Hermetic |
|
Electrical Connector |
MIL-C-5015 |
|
Electrical Connection
Position |
Top |
|
SUPPLIED ACCESSORIES:
|
Model 081A40 Mounting Stud
(1) |
Model ICS-1 NIST-traceable
single-axis amplitude response calibration from 600 cpm (10
Hz) to upper 5% frequency (1) |
OPTIONAL
VERSIONS |
CS- Canadian
Standards Association Approved Intrinsically
Safe |
| |
Hazardous Area
Approval |
Cl I, Div I, Groups
A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
|
|
Hazardous Area
Approval |
Exia IIC T4, AExia
IIC, T4 |
|
Hazardous Area
Approval |
Cl I, Div 2, Groups
A, B, C, D; ExnL IIC T4, AExnA IIC T4 |
|
EX- Hazardous
Area Approval- contact factory for specific
approvals |
| |
Hazardous Area
Approval |
EEx ia IIC T4,
-54°C≤Ta≤121°C, II 1 G |
|
|
Supplied
Accessory : Model M081A61 Mounting Stud 1/4-28 to M6 X 1
(1) | All specifications are at room temperature
unless otherwise specified.
|
NOTES: |
[1] |
Typical. |
[2] |
Conversion Factor 1g = 9.81
m/s². |
[3] |
The high frequency tolerance is
accurate within ±10% of the specified frequency. |
[4] |
1Hz = 60 cpm (cycles per
minute). |
[5] |
Zero-based, least-squares,
straight line method. |
[6] |
1/4-28 has no equivalent in S.I.
units. |
[7] |
See PCB Declaration of
Conformance PS023 for details. |
|
[7] |
|
|