607A61  Photo Industrial monitoring Instrumentation

Model 607A61
Product Type: Accelerometer, Vibration Sensor
Low profile industrial ICP® accel, 100 mV/g, 0.5 to 10k Hz, side exit, 10-ft armored jacketed cable & swiveler base
View Spec Sheet (PDF)
View photo and drawing .
PERFORMANCE ENGLISH SI
Sensitivity(± 15 %) 100 mV/g
10.2 mV/(m/s²) [2]
Measurement Range ± 50 g
± 490 m/s²
Frequency Range(± 3 dB) 30 to 600,000 cpm
0.5 to 10,000 Hz
Resonant Frequency 1500 kcpm
25 kHz [1]
Broadband Resolution(1 to 10,000 Hz) 350 µg
3434 µm/sec2 [1]
Non-Linearity ± 1 %
± 1 % [3]
Transverse Sensitivity ≤ 7 %
≤ 7 %
ENVIRONMENTAL
Overload Limit(Shock) 5000 g pk
49,050 m/s² pk
Temperature Range -65 to +250 °F
-54 to +121 °C
Temperature Response See Graph
See Graph [1]
Enclosure Rating IP67
IP67
ELECTRICAL
Settling Time(within 1% of bias) ≤ 2 sec
≤ 2 sec
Discharge Time Constant ≥ 0.3 sec
≥ 0.3 sec
Excitation Voltage 18 to 28 VDC
18 to 28 VDC
Constant Current Excitation 2 to 20 mA
2 to 20 mA
Output Impedance <150 ohm
<150 ohm
Output Bias Voltage 8 to 12 VDC
8 to 12 VDC
Spectral Noise(10 Hz) 8 µg/√Hz
78.5 (µm/sec2)/√Hz [1]
Spectral Noise(100 Hz) 5 µg/√Hz
49.1 (µm/sec2)/√Hz [1]
Spectral Noise(1 kHz) 4 µg/√Hz
39.2 (µm/sec2)/√Hz [1]
Electrical Isolation(Case) >108 ohm
>108 ohm
PHYSICAL
Size (Hex x Height) 9/16 in x 1.0 in
14 mm x 25.4 mm
Weight(without cable) 1.1 oz
31 gm [4]
Mounting Stud
Stud
Mounting Thread 1/4-28 Male
Not Applicable [5]
Mounting Torque(stud) 7 to 8 ft-lb
9.5 to 10.8 N-m [6][7]
Mounting Torque(hex nut) 2 to 5 ft-lb
2.7 to 6.8 N-m
Sensing Element Ceramic
Ceramic
Sensing Geometry Shear
Shear
Housing Material Stainless Steel
Stainless Steel
Sealing Welded Hermetic
Welded Hermetic
Electrical Connector Integral Armored Cable
Integral Armored Cable
Electrical Connection Position Side
Side
Cable Length 10 ft
3.0 m
Cable Type Polyurethane
Polyurethane [8]
SUPPLIED ACCESSORIES:
Model 080A156 Mounting Base (1)
Model ICS-2 NIST-traceable single-axis single-point amplitude response calibration at 6000 cpm (100 Hz)
OPTIONAL VERSIONS
EX- Hazardous Area Approval- contact factory for specific approvals
Hazardous Area Approval EEx nL IIC T4, -40°C≤Ta≤121°C, II 3 G
Hazardous Area Approval EEx nL IIC T4, -40°C≤Ta≤121°C, II 1 G
Hazardous Area Approval Cl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I
Hazardous Area Approval Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4
Hazardous Area Approval Exia IIC T4, AExia IIC, T4
M- Metric Mount
Supplied Accessory : Model M080A159 Mounting stud, 1/2-20 to M6 x 1 (1) replaces Model 080A156
TO- Temperature Output
Temperature Output Range +36 to +250 °F
+2 to +121 °C
Temperature Scale Factor 5.56 mV/°F + 32
+10 mV/°C
Electrical Connector Integral Armored Cable
Electrical Connections(Red) Acceleration Output
Electrical Connections(Black) Ground
Electrical Connections(White) Temperature Output

All specifications are at room temperature unless otherwise specified.
NOTES:
[1] Typical.
[2] Conversion Factor 1g = 9.81 m/s².
[3] Zero-based, least-squares, straight line method.
[4] Measured with mounting stud.
[5] 1/4-28 has no equivalent in S.I. units.
[6] 1/8" hex Allen key required for English version, 4 mm hex Allen key required for Metric version.
[7] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[8] Stainless steel armor jacket over twisted shielded pair.
[9] See PCB Declaration of Conformance PS023 or PS060 for details.



[9]



607A61  Photo



Download Drawing 13444-B.pdf

Download Drawing 18551-NR.pdf
Top